UK Liquid Rubber · Forti Nova

Below-ground liquid waterproofing: specify the structure

Liquid rubber basement waterproofing must be considered as part of the complete structural waterproofing design. Water pressure, substrate, drainage, joints and membrane protection determine the appropriate system.

Request below-ground system advice

01Start with water exposure

Explain whether the project is a basement, foundation or retaining wall; whether it is new or existing; and where water is entering. Supply available drawings, drainage information and details of the surrounding ground.

02Specify a complete waterproofing approach

Consider joints, penetrations, water pressure, accessible application faces and interaction with drainage. The appropriate designer or specialist must assess the structure and select the system. A coating alone is not a universal answer to below-ground water ingress.

03Protect the completed membrane

Where a membrane is covered, the specification must address protection during following work and compatibility with drainage or other layers. Agree inspection and detailing before areas become inaccessible. Request system advice before purchasing roof-coating quantities for this use.

Direct answer

How do you waterproof a basement or retaining wall?

Below ground waterproofing keeps water out of a structure that is permanently in contact with wet ground, so it depends on a continuous barrier with no interruptions and a drainage path for any water that reaches it. Liquid rubber is applied to the outside face of the wall and slab as a seamless 2 mm membrane, with protection board over it, and internal drainage and a sump handle residual moisture. Joints, pipe entries and the wall to slab junction are the details that decide whether it works.

Approach
Continuous external membrane with drainage and protection
Membrane
2 mm seamless liquid rubber, fully bonded
Critical details
Wall to slab junction, joints, pipe entries, tie holes
Protection
Protection board or drainage membrane over the coating
Application
Cold applied, no flame in a confined space
Water table
Assessed at survey: it decides the system, not the price

How it works

The three parts of a below ground system

Water below ground is not a leak that can be patched, it is a permanent condition. A below ground system therefore has three parts: a continuous waterproof barrier on the structure, protection for that barrier while backfill goes in, and a drainage route so any water arriving at the wall is taken away rather than left to build pressure.

The barrier is the part people focus on and the part most likely to be compromised, not by the membrane but by what happens after it. A coating damaged by a digger bucket is a hole. That is why protection board is not an optional extra on a below ground job.

Details

Where below ground waterproofing fails

Almost every basement leak traces to a junction. The wall to slab junction, construction joints, movement joints, service pipe entries and tie holes are all interruptions in the concrete, and each one has to be treated as a detail rather than being buried under the general coat.

Those details are filled, sealed and reinforced with fabric before the field membrane is applied. Pipe entries get a proper boot or flange detail. Where a movement joint is designed to move, the waterproofing detail has to accommodate that movement rather than rigidly bridging it.

Drainage matters too. Even a well built system benefits from a drainage layer that takes water down to a sump, because hydrostatic pressure is what pushes water through the smallest defect.

  • Wall to slab junction reinforced and sealed
  • Construction and movement joints detailed individually
  • Service pipe entries with proper flange or boot details
  • Tie holes filled and sealed
  • Protection board before backfill
  • Drainage layer and sump to relieve pressure

Practicalities

Cold application and working in a basement

Torch applied membranes in a basement mean flame in a confined space, plus hot works permits, ventilation and fire watch. A cold applied liquid rubber removes that entire risk category, which matters on occupied buildings and on jobs where access is a stairwell rather than a roof.

Internal tanking is possible where external access is impossible, but it is a different design decision: water is still in the structure and the system relies on the coating holding it back plus drainage to manage it. That trade off is discussed openly before specification rather than discovered after the first winter.

The problems this solves

Water pressure rather than water flow

Below ground, water arrives under hydrostatic pressure and finds the smallest defect. Continuity and detail work matter more than membrane thickness.

Leaking wall to slab junction

The most common basement leak. It is reinforced and sealed as a specific detail, not covered by the field coat.

Damaged membrane during backfill

A coating without protection board can be punctured before the ground is even reinstated. Protection is part of the specification.

Hot works in confined spaces

Cold applied systems remove flame, permits and fire watch from a basement programme entirely.

Where liquid rubber suits below ground work

A seamless, fully bonded, cold applied membrane suits walls and slabs where continuity and access are both difficult.

Structures
Basements, retaining walls, lift pits and underground rooms
Membrane
2 mm seamless liquid rubber, no laps to fail
Application
Cold applied by brush, roller or spray
Protection
Protection board or drainage membrane before backfill
Drainage
Perimeter drainage and sump to relieve pressure
Compare cost and programme for your project

Questions answered

Can you waterproof a basement from the inside?

It is possible with an internal tanking system plus drainage, but it is a compromise: the water remains in the structure. Where external access allows, waterproofing the outside face is the better solution.

How long does below ground waterproofing last?

A correctly detailed, protected liquid rubber membrane is designed to last the life of the structure. The variables are the detail work, the protection during backfill and whether drainage keeps pressure off it.

Do I need a drainage system as well?

In most below ground situations yes, and it is good practice even where the membrane is sound. Relieving hydrostatic pressure protects the whole system and gives any unexpected water somewhere to go.

Is liquid rubber suitable for a lift pit or plant room below ground?

Yes. These are small, detail heavy spaces where a seamless cold applied membrane avoids laps and avoids flame in a confined area.

Questions before you specify

Can liquid rubber be used for foundation waterproofing?

A liquid-applied coating may be considered within an appropriate foundation waterproofing specification, subject to the exact product and system approval. Confirm the water exposure, application side, substrate condition, joints and protection before selecting a product. A generic roof coating specification is not sufficient.

Will coating the inside of a basement stop every leak?

No. Water may be driven through joints or behind a coating by ground-water pressure. The building needs a structural waterproofing assessment. For retaining wall waterproofing, also establish drainage and the protection required before backfilling. Send drawings and site conditions for system advice.